BLUE SEA Battery Monitor

SVB item number: 75399 Manufacturer no.: 7635
Battery monitor for 12 V on-board systems with two-step undervoltage protection with visible alarm (when reaching the 1. step), below the second step it switches off.
Product details
only  €132.95
2 | in stock
pcs.
Having issues?
If you are not redirected to PayPal, it could be due to your browser settings. Please check and if necessary deactivate the setting "Hide IP address" in the settings -> Safari -> Hide IP address. Please also check your browser for updates.
MyBoat
Are you already using this item?
Add to my boat now.

Product data

  • SVB item number 75399
  • EAN 632085076351
  • Manufacturer no. 7635
  • Description BLUE SEA - m-LVD Battery Monitor
  • Device type Battery Monitor

Accessories

Image of Microfuse Holder / 5x20
Microfuse Holder / 5x20
Image of Micro Fuse 5x20 / fast-acting
-20%
SEATEC Micro Fuse 5x20 / fast-acting
Image of Spade Connector Female / blue / 1.5 - 2.5 mm² / pack of 15
Spade Connector Female / blue / 1.5 - 2.5 mm² / pack of 15

Product details

The m-LVD (LVD = Low Voltage Disconnect) battery monitor can be used for 12 V on-board systems and monitors the battery voltage. At a certain low voltage, the integrated relay disconnects the consumer from the electrical system. Thus, an accidentally discharge of the battery is prevented.
The standard setting is set at 12.1 V and can be changed with the included ON-OFF-ON remote between 11.3 - 12.1 V (in 0.2 V steps). The remote makes the handling easy and the integrated LED works as a visual alarm.
Thanks to a well-defined hysteresis, short voltage drops and voltage spikes, that can occur by switching on and off of strong consumers, do not cause false tripping.
This relay provides a two-step undervoltage protection. About 5 minutes before disconnection, the visual alarm signalizes the undervoltage (through red LEDs). The LEDs are not lit up during normal voltage levels. At a continuing undervoltage level the LEDs light up red, after disconnection they flash red. An acoustic alarm is also possible. For that the optional Aural Warning / Piezo, Art. 23403 can be used.
The disconnection of the consumers can be delayed through the remote by 10 minutes during an alarm (button OVERRIDE) or can be used as a direct switch (button OFF), to shut down the consumers immediately. Through pressing the buttons the alarm can be deactivated (visual & acoustical).
At a voltage of > 13 V, battery and consumer are automatically reconnected.
The housing allows recessed or bulkhead installation.
The electrical connection is done over a 6mm tap bolt as well as over a 6.3mm flat plug.

Details:
  • rated voltage: 12 V
  • power: max. 115 A (5 min)
  • continuous power: 65 A
  • consumption:
    95 mA (battery/consumer connected), 4 mA (battery/consumer disconnected)
    max. power for acoustic alarm: 250 mA
    max. power for external alarm LED: 14 mA
  • connections:
    connecting bolt: M6
    main electric circuit = 2x tap bolts 6.3 mm (1/4"-20), tightening torque max. 6.78 Nm (60 in-lb)
    control panel wiring (device) = 4x 6.3 mm flat plug
    control panel wiring (remote) = 8x 6.3 mm flat plug
  • max. cable cross-section: 50 mm²
  • low-voltage protection (adjustable from 11.3 to 12.1 Volts - in 0.2V intervals)
  • Measurements: 73 x 73 x 66 mm (2.85" x 2.85" x 2.57")
  • Weight: 0,35kg (0.77 lb)
  • Advice: Battery Automatic Relay does not protect from power surge.
Settings (standard setting at 12.1 V):
Press and hold button OVERRIDE - the flashing LED shows the programming mode.
Continue rapidly:
per pressing the button OFF the setting is reduced by 0.2 V,
per pressing the button OVERRIDE the setting is increased by 0.2 V,
the frequency of flashing displays the programmed amount:
5-time flashing = 12.1 V = standard setting
4-time flashing = 11.9 V
3-time flashing = 11.7 V
2-time flashing = 11.5 V
1-time flashing = 11.3 V
To end the programming, please do not press any button for 20 seconds.
The device will change into the normal operating mode after this time.

Documents

en-flag Manual
.PDF (1,02 MB)
Item 75399

Product safety

What other SVB customers have to say

100% real reviews

3 customer reviews

4 (out of 3 ratings)
2 Stars
(0)
1 Stars
(0)
Wo&Wo  G.
by Wo&Wo G. Flag of Austria 2/20/2015 Verified purchase
alles ok gutes Produkt
Norbert  L.
by Norbert L. Flag of Germany 10/27/2014 Verified purchase
Stabile Bauform ausreichende Verdrahtung.
Neto S.
by Neto S. Flag of Singapore 9/19/2014 Verified purchase
I had written to SVB (17Sept) but until now (20Sep) I had received no reply on the status of my order.\r\n\r\nI checked on the tracking website:\r\nhttp://nolp.dhl.de/nextt-online-public/set_identcodes.do?lang=en&idc=288035783273&rfn=&extendedSearch=true. But now it shows that it is transferred to Saudi Post. When I enter the tracking number given on the Saudi Post tracking link (http://www.sp.com.sa/English/Eservices/Pages/TrackandTrace.aspx?ShippingMethod=1&TrackingNumber=288035783273&DetailedControl=Path_DisplayShipmentRequestData), there is an error message saying \"Please enter the tracking number.\"\r\n\r\nOf course, it is right to say that DHL is not to be blamed but SVB should had keep buying customers informed of the delivery stages before the payment site. Had I know that this package will be going through Saudi Post, then I would had it shipped to Singapore and from there ask my colleagues who are coming to Saudi to hand carry to me. This way it would be faster.\r\n\r\nI had lost three packages (with tracking numbers) sent through Saudi Post.

Rate product

How would you rate this product?
Disappointed
Completely fails to meet my expectations
Poor
Only some expectations are met
OK
Meets my basic expectations
Good
Slightly better than my general expectations
Excellent
Fully exceeds my expectations
Click on the stars to rate

Customers ask customers

No questions asked yet. Be the first to ask a question!

E-mail Newsletter

Product news, offers & new guide videos. Stay up to date!

WhatsApp

New: Get news from SVB straight to your phone!