STERLING ZINC SAVER II Galvanic Isolator

SVB item number: 23404 Manufacturer no.: 7190-1
Prevent major galvanic damage to your boat and reduce the use of your anodes! Stop excess zinc loss by installing this galvanic isolator.
Product details
Recommended retail price: €136.85
only  €129.95
-5%
You save: €6.90
25 | in stock
pcs.
Having issues?
If you are not redirected to PayPal, it could be due to your browser settings. Please check and if necessary deactivate the setting "Hide IP address" in the settings -> Safari -> Hide IP address. Please also check your browser for updates.
MyBoat
Are you already using this item?
Add to my boat now.

Product data

  • SVB item number 23404
  • EAN 5060068290428
  • Manufacturer no. 7190-1
  • Description ZINC SAVER II / 30A galvanic isolator

Accessories

Image of Onboard System / Shore Panel Indicator Panel LAR
-5%
PHILIPPI Onboard System / Shore Panel Indicator Panel LAR
only €39.95
Image of Tef-Gel / Corrosion Stopper
TIKAL Tef-Gel / Corrosion Stopper
from €10.95 (€1,095.00/ kg)

Product details

According to CE guideline ISO EN 13297, the shore power protective conductor (PE) must be connected to the boat's negative DC earth. This means that saildrives, motors, valves and much more are almost always automatically connected to the on-shore ground conductor. All new yachts have this connection as standard.

Galvanic damage: Due to the connection between the ground conductor and the negative DC grounding, there may be galvanic compensation currents between your vessel and a neighboring yacht, the marina or other objects in the water. This can cause bronze valves to dissolve or entire rudder systems to break down under stress. The metal, which is inferior in an electrochemical series, sacrifices itself for the higher quality metal. Ultimately, if your yacht is protected by anodes, it only makes sense to protect your anodes as well, right?

If a neighboring vessel or marina has no anodes, your anodes will be used for protection. If these are consumed or are not sufficient enough, you have a serious problem. Unexpected corrosion can then destroy the saildrive, drivetrain, valves or other components. Replacing these components is very expensive and complex.


By installing this galvanic isolator, you can reduce the wear and tear of zinc anodes, seeing as the anodes do not automatically protect the entire marina and neighboring yachts.

This unit complies with the requirements of ISO EN13297 and ISO 8846.
Dimensions: 220 x 110 x 100 mm.
Connection: 2x 6 mm threaded bolts


Notes
You will receive the 30 amp version.
We are often asked why 30 amps, as most mains faults operate the RCD on the boat, i.e. they are relatively very small.
This is true in theory, but you also have to take into account that the RCD may not trip.
In this case, a short-circuit current would run through the (green/yellow) protective earth conductor, which in the event of the largest possible fault would be protected by the circuit breaker (fuse) on the jetty.

Accordingly, this unit is calibrated in such a way that, in the event of a serious fault in the 230 V on-board system, it can discharge the (fault) rated current, in this case 30 A, to earth via the protective earth conductor for 24 hours without the heat sink temperature exceeding 90°C.

Ideally, the galvanic isolator should be installed as close as possible to the shore power commutation. The temperature of the unit is normally the same as the ambient temperature. However, the device may become hot due to a high fault current leakage caused by a serious fault in the onboard system. Therefore, mount the unit in a place that is heat-resistant, as dry as possible, well ventilated and keep at least 10 cm free space on all sides.
Waterproof versions, e.g. the STERLING ProSave W 32A, are available for use in environments exposed to high levels of moisture/humidity. Please contact us if you have any questions!

Note
Since the zinc saver is not "fail safe" certified - its functionality or a failure should be monitored visually or acoustically, e.g. with a shore power indication panel LAR.

Documents

multi-flag Manual
.PDF (1,11 MB)
Item 23404
de-flag Short manual
PDF (178,23 KB)

Systems

Preview system drawing
Victron
Preview system drawing
Shore Power Connection with Inverter

Product safety

What other SVB customers have to say

100% real reviews

30 customer reviews

4.7 (out of 30 ratings)
2 Stars
(0)
1 Stars
(0)
100% recommend SVB
  • Advantages
  • Weight (1)
  • Size (1)
  • Noise Level (1)
  • Operation (1)
  • Price/performance ratio (1)
  • Quality (1)
  • Effect (1)
  • Mounting/Installation (1)
David M.
by David M. Flag of United Kingdom 11/3/2017 Verified purchase
Hopefully fit and forget.
Axel H.
by Axel H. Flag of Seychelles 4/18/2017 Verified purchase
Everything as always, I am very satisfied with the competent advice and the timely answers
Michele G.
by Michele G. Flag of Italy 9/1/2016 Verified purchase
Installed in 15 minutes. Exactly what I expected.
Thomas K.
by Thomas K. Flag of Germany 6/10/2016
Very good
Highly recommended. Easy installation, brilliant effect.
Anytime again.
daniel C.
by daniel C. Flag of France 5/9/2016
satisfied
Easily installed and meets my expectations

Rate product

How would you rate this product?
Disappointed
Completely fails to meet my expectations
Poor
Only some expectations are met
OK
Meets my basic expectations
Good
Slightly better than my general expectations
Excellent
Fully exceeds my expectations
Click on the stars to rate

Customers ask customers

General question
Mantas J. | Apr 25, 2023 Flag of English
User image of Mantas J.

is this ZS30A or ZS30C model? as there are two models for 30A isolator.

Answer
W P. | Apr 25, 2023
User image of W P.

We have the ZS30A version in our standard range. If you want the ZS30C with an integrated capacitor send us an email to [email protected]