SIEMENS Shore Connection Unit with Arc Fault Detection Device (AFDD) and Circuit Breaker (RCD/RCCB)

SVB item number: 52909
Shore connection unit with Arc Fault Detection Device (AFDD) and Circuit Breaker (RCD/RCCB) for permanent installation on the boat dock. Only with constant 230 V on-board power supply control, also suitable for use on board. Product details
only  €242.95
6 | in stock
pcs.
Having issues?
If you are not redirected to PayPal, it could be due to your browser settings. Please check and if necessary deactivate the setting "Hide IP address" in the settings -> Safari -> Hide IP address. Please also check your browser for updates.
MyBoat
Are you already using this item?
Add to my boat now.

Product data

  • SVB item number 52909
  • Description Shore connection unit with fire protection breaker
  • Accessories for Shore power connections

Accessories

Image of Onboard System / Shore Panel Indicator Panel LAR
-5%
PHILIPPI Onboard System / Shore Panel Indicator Panel LAR
only €39.95

Product details

Never been seen before!
Protection for cables, operators and against fire in a 230 V shore power unit.
This unit provides total protection in case of residual current, short circuits and overloads, as well as arcs which can occur in 230 V installations with loose terminal/plug connections, cable breaks or insulation damage, or with defective connection lines.
Common installations with RCDs and RCCBs cannot detect possible arcs in defective electrical equipment and it is statistically proven that arcs in electrical systems are among the most frequent causes of fire.

CAUTION:
When connecting the device, pay particular attention to the position of the L and N connections, which is only guaranteed with proper CEE plug connections. A Schuko plug connection or lengthening the feed cable is not permitted and should be avoided. Always make sure the L1 and N phase position is correctly connected and does not change, this must be permanently monitored. If you cannot guarantee this, the reverse polarity protected version should be used.

If you sleep on board your boat or caravan, and at the same time run chargers, fan heaters or cooling devices, you should use this innovative and compact shore power unit for an all-round safe AC power supply and to avoid possible fires caused by electrical equipment in the on-board AC network!


Small but nice!
The combination of a compact SIEMENS RCD/RCCB breaker and innovative AFDD fire circuit-breaker only requires the space of 2 dividing units, 1 dividing unit = 17.5-18 mm) in a small distribution box.

Residual Current Device / Circuit Breaker (RCD/RCCB)
The integrated SIEMENS residual current circuit breaker ensures the required personal protection for residual currents > 30 mA and short-circuit and overload protection for currents of 16 A. It works exactly the same as previous (RCD/RCCB) switches, but takes up considerably less space.

Fire Protection Breaker (AFDD)
The integrated SIEMENS fire protection breaker (Arc Fault Detection Device, or AFDD for short) first detects dangerous electric fault arcs, such as those that can occur at serial line damage points, i.e.. non-secure contacts such as loose screw or plug contacts. These faults are not detected by the RCD/RCCB breaker!
The AFDD also detects arcs that can occur as a result of insulation faults between active conductors or against the protective conductor.
In both cases, the circuit is quickly and reliably broken, preventing electrically ignited fires.
Insulation faults occur on board, for example, due to vibrations, thermal expansion and shrinkage, mechanical stress, corrosion and ageing.

Plastic housing (small distribution box or overload protector box) with transparent door
Grey surface mounted housing (RAL 7035), waterproof to IP65 with DIN rail, suitable for 3 dividing units, four rear mounting holes with a diameter of 5.5 mm. Dimensions (H x W x D): 96 x 100 x 150 mm.

Documents

en-flag Datasheet
PDF (326,88 KB)
en-flag Datasheet
PDF (372,82 KB)
multi-flag Manual
PDF (1,11 MB)
multi-flag Manual
PDF (3,37 MB)

Systems

Product safety

What other SVB customers have to say

100% real reviews

3 customer reviews

3.7 (out of 3 ratings)
4 Stars
(0)
3 Stars
(0)
2 Stars
(0)
Frank S.
by Frank S. Flag of Germany 1/17/2020
Congratulations, the first to offer this clever fire protection technology for boats!
I know these relatively new fire protection switches from the electrical installation area very well. An innovation in the otherwise conservative world of electricians. The devices monitor the individually secured 230V circuit for unwanted electrical interruption due to, for example, wire break cable crushing or loose connection, as well as defective device switches. Even "hissing" socket distributors are recognized and if a dangerous arcing fault occurs, it is switched off confidently before the fire starts. It is incomprehensible to me why so little is said about it so far. As an alternative to the regular fixed installation on the ship, the technology can also be accommodated in a mobile plug adapter housing between the shore connection and the on-board power plug.
Uwe J.
by Uwe J. Flag of Germany 1/17/2020
Simply ensure a clear conscience!!
Hello ! Practical small box with the most important protective devices for 230V cables, sockets and Co. on board. The best thing to do is to install it in a dry area so that you can get there later to regularly check the residual current protection (test button), the fire protection switch checks itself. The box is splash-proof, but dry protects the components better !! Especially on the ship, you'd better press the test button a little more often - I know this will be 'forgotten' at home, but it's very important !! And take the opportunity to have sockets, CEE plugs and the shore connection cables checked for damage, so that nothing happens in bad weather !! -) Hand width!
Mate O.
by Mate O. Flag of Hungary 1/25/2023
Not certified for suggested use
Almost all boat networks have multiple circuits while the AFDD must not be used as a distribution root switch (arc fault protection won't be effective).

Rate product

How would you rate this product?
Disappointed
Completely fails to meet my expectations
Poor
Only some expectations are met
OK
Meets my basic expectations
Good
Slightly better than my general expectations
Excellent
Fully exceeds my expectations
Click on the stars to rate

Customers ask customers

No questions asked yet. Be the first to ask a question!

E-mail Newsletter

Product news, offers & new guide videos. Stay up to date!

WhatsApp

New: Get news from SVB straight to your phone!

SIEMENS Shore Connection Unit with Arc Fault Detection Device (AFDD) and Circuit Breaker (RCD/RCCB)
View Ratings (3) Questions (0)