Sensor EV-1
ACU-200 Drive Control Unit
Operational device p70Rs
Type 1 hydraulic pump
Evolution cable set:
Technical data - Type 1 hydraulic pump
| Power supply | 12 V |
| For cylinder volume | 80 - 230 ccm (4.9 - 14.0 in3) |
| Maximum flow rate (no load) |
1000 ccm/min (61.0 in3/min) |
| Dimensions (h x w x d) | 199 x 103 x 89 mm |
Technical data - EV-1 sensor
| Nominal on-board voltage | 12 V (power supply via SeaTalkng) |
| Operating voltage range | 10.8 to 15.6 V DC |
| Power consumption (amps) | 30 mA |
| Sensors | Three-axis digital accelerometer, Three-axis digital compass and three-axis digital angular rate sensor |
| Data connection | SeaTalkng |
| Operating temperature | -20 to +55 °C |
| Storage temperature | -30 to +70° C |
| Relative humidity | max. 93% |
| Water rating | IPX6 |
| Diameter | 140 mm |
| Depth | 35 mm (including housing) 95 mm (including bracket) |
| Weight | 0.29 kg |
Technical data - p70Rs control unit
| Nominal voltage | 12 V DC |
| Voltage range | 9 to 16 V DC |
| Display Size | 3.5" |
| Display | Optically integrated, sunlight-readable LCD display |
| Resolution | 320 x 240 QVGA |
| Colours | 16 bit colour resolution (64,000 colours) |
| Colour palettes | Four colour palettes - two day, inverse and red/black |
| LCD brightness | 1;200 nit |
| current consumption (watts) | 1:6 watts |
| Connectors | SeaTalk and SeaTalkng compatible with NMEA2000 marine networks |
| Operating temperature | -25º C to 55º C (-13º F to 131º F) |
| Storage temperature | -30º C to 70º C (-22º F to 158 ºF) |
| Relative humidity | Maximum 93 % |
| Waterproof to | IPX6 |
| Compliance | Europe: 2004/108/EC | Australia and New Zealand: C-Tick Compliance Level 2 |
| Included in delivery | Instructions, seal, display, sun cover, replacement frame, mounting screws |
I Have a boat AQUADOR 27 with engine build VOLVO D6 -310A-B AQ/PS inside out leg DPH A1.76.tHIS PILOT IS ok; AHD This package includes everything I need for the installation; Thanks
If the boat has fully hydraulic steering and the main steering cylinder has a volume between 80-230cc, this is the correct autopilot. Additionally required items, such as a spear block and connection material for the hydraulic pump are not included in this package. The cables supplied are also sufficient for a technically correct installation, but whether the lengths of the cables supplied are sufficient cannot be judged from here.