The Lynx Distributor from VICTRON is part of the modular Lynx distribution system and consists of a positive and a negative busbar. The positive busbar features four fused connections including fuse monitoring, while the negative busbar has four connections and a ground connection. The distributor can be connected to other Lynx devices with M10 connections.
The connectors are suitable for inverters/chargers, DC loads and other charging devices such as solar charge controllers. If more than four connectors are needed, additional modules can be added. Please note that only Lynx modules with M10 connectors can be connected to each other.
LED display
The Lynx Distributor also has an LED indicator for the respective fuse status. Since the Lynx Distributor does not have a built-in power supply to supply the fuse detection circuit, the distributor must be connected to a Lynx Shunt VE.Can or Lynx Smart BMS (not supplied by us) using the RJ10 cable included in the delivery contents. Operating status and the status of each fuse are also transmitted via the RJ10 cable. This data can be accessed via the VictronConnect app (only with the Lynx Smart BMS), the GX device and the VRM portal.
Fuses
The Lynx Distributor is designed to accommodate MEGA fuses. These are sold separately.
Technical data:
| Voltage range |
9 - 60 VDC |
| Supported operating voltages |
12, 24 or 48 V |
| Reverse polarity protection |
Yes (but not the RJ10 connector) |
| Nominal current |
1000 ADC uninterrupted |
| Power consumption |
max. 100 mA (when all LEDs are lit) / Power supply via Lynx Shunt VE.Can or Lynx Smart BMS |
| Busbar connection |
M10 |
| Fuse connection |
M8 |
| Power supply connection |
RJ10 cable (40 cm) included |
| Data connection |
RJ10 cable (40 cm) included. RJ10 cable (40 cm) included. Data can only be received from the Lynx Smart BMS ABS |
| Case material |
ABS |
| Case dimensions (LxWxD) |
290 x 170 x 80 mm |
| Weight |
2.2 kg |
| Material busbar |
Tinned copper |
| Busbar dimensions (WxH) |
30 x 8 mm |
| Operating temperature |
-40 to +60°C |
| Storage temperature |
-40 to +60°C |
| Humidity |
Max. 95 % (non-condensing) |
| Protection category |
IP22 |
Note:
1.
Please note that the M10 connection refers to the busbar connections to which you can connect additional Lynx modules. It is not possible to connect M8 and M10 devices together.
2. The fuse and cable connection bolts in the module always have an M8 thread.
3. The RJ10 connection is not protected against polarity reversal. Incorrect RJ10 connection can irreversibly damage the electronic circuits of the Lynx Distributor.
4. No communication is possible in combination with the Lynx Shunt VE.Can, only power supply