| Voltage range | 9 - 60 VDC |
| Supported operating voltages | 12, 24 or 48 V |
| Reverse polarity protection | No |
| Uninterruptible rated current of the main contactor | 1000 A |
| Peak current rating of the main contactor | 1200 A for 5 minutes |
| Busbar connection | M10 |
| Current consumption in OFF mode | 0.3 mA for all system voltages |
| Power consumption in standby mode | approx. 0.6 W (50 mA at 12 V) |
| Power consumption during operation | Approx. 4.2 W (350 mA at 12 V) |
| Minimum load resistance for precharging | 10 ohm and more for 12 V 20 ohms and more for 24/48 V |
| Maximum rated current of the AUX output | 1.1 A uninterruptible |
| Allow charging connection (ATC) maximum rated current | 0.5 A at 60 VDC, protected by resettable fuse |
| Allow discharge connection (ATD) maximum rated current | 0.5 A at 60 VDC, protected by resettable fuse |
| Programmable relay (SPDT) maximum rated current | 1 A at 60 VDC |
| VE.Can | RJ45 |
| I/O | Detachable multi-connector with screw terminals |
| Battery BTV cable | Plug and socket of the 3-pin connector with M8 screw ring |
| Fuse monitoring for Lynx Distributor (up to 4 modules) | RJ10 (a cable is supplied with each Lynx Distributor) |
| Housing material | ABS |
| Housing dimensions (HxWxD) | 230 x 180 x 100 mm |
| Housing weight | 2.7 kg |
| Busbar material | Tin-plated copper |
| Dimensions of the busbar | 8 x 30 mm |
| Operating temperature range | -40 to 60 °C |
| Storage temperature range | -40 to 60 °C |
| Humidity | Max. 95% |
| Protection class | IP22 |