PHILIPPI Onboard System / Shore Panel Indicator Panel LAR

SVB item number: 33192 Manufacturer no.: 010000231
According to DIN EN ISO 13297, boats with a 230 V on-board power supply should be provided with an indicator that shows the correct electrical connection of the AC onboard system to the AC shore power (reverse polarity, protective earth conductor not connected). This small LAR mains control panel from PHILIPPI is easy to install and features two indicator lights to show the correct electrical connection between the shore power connection from the jetty and the on-board AC mains. Product details
Recommended retail price: €42.00
only  €39.95
-5%
You save: €2.05
41 | in stock
pcs.
Having issues?
If you are not redirected to PayPal, it could be due to your browser settings. Please check and if necessary deactivate the setting "Hide IP address" in the settings -> Safari -> Hide IP address. Please also check your browser for updates.
MyBoat
Are you already using this item?
Add to my boat now.

Product data

  • SVB item number 33192
  • EAN 4250214631002
  • Manufacturer no. 010000231
  • Description PHILIPPI - Onboard system / shore panel indicator panel LAR
  • Accessories for Shore power connections

Must-haves

Image of Spade Connector Female / red / 0.5 - 1.5 mm² / pack of 15
Spade Connector Female / red / 0.5 - 1.5 mm² / pack of 15
Image of Rubber Installation Cable
Rubber Installation Cable

Product details

According to DIN EN ISO 13297, boats with a 230 V on-board power supply should be provided with an indicator that shows the correct electrical connection of the AC onboard system to the AC shore power (reverse polarity, protective earth conductor not connected). This small LAR mains control panel from PHILIPPI is easy to install and features two indicator lights to show the correct electrical connection between the shore power connection from the jetty and the on-board AC mains: The green light signals that everything is connected correctly and the red light indicates reverse polarity of the outer conductor (live L) and neutral (N).
Because the LAR indication panel detects a break in the protective earth conductor (PE), it is a useful addition to the function monitoring of galvanic isolators that are not "fail safe" certified. As soon as there is a break in the protective conductor (PE), both control LEDs light up.

Tech data
  • Mains voltage 230V AC / 50 Hz
  • Measuring error current 1.4 mA
  • Dimensions: W 105 x H 52.5 x D 50 mm

Notes
  • Not suitable for AC mains without protective earth.
  • Connection requires a 3x 1.5 mm² cable and fully isolated flat connectors.
  • Suitable for function checking of galvanic isolators that are not "fail safe" certified.

Installation notes
Ideally, the L and N connection cables of the LAR wiring system control panel should be connected upstream of the residual current circuit breaker (RCBO). The green/yellow PE protective conductor is connected to the protective conductor busbar in the shore connection unit.
This ensures that a polarity reversal is also displayed if the RCBO has tripped (for whatever reason).
If there is a galvanic isolator (zinc saver) on board, which can be found in the green/yellow PE cable between the shore power takeover and the shore connection unit if installed correctly, it is also monitored for continuity.

Philippi lar,polarity indicator,shore power,


Documents

multi-flag Manual
PDF (49,71 KB)

Product safety

What other SVB customers have to say

100% real reviews

6 customer reviews

4.8 (out of 6 ratings)
3 Stars
(0)
2 Stars
(0)
1 Stars
(0)
100% recommend SVB
Hubert R.
by Hubert R. Flag of Italy 1/7/2023 Verified purchase
unfortunately not yet installed, therefore only 4 stars
for what it is intended for!

Rate product

How would you rate this product?
Disappointed
Completely fails to meet my expectations
Poor
Only some expectations are met
OK
Meets my basic expectations
Good
Slightly better than my general expectations
Excellent
Fully exceeds my expectations
Click on the stars to rate

Customers ask customers

Technical question
Matteo B. | Dec 17, 2023 Flag of English
User image of Matteo B.

good morning, is there any diagram/picture on how to wire the panel? its unclear to me where exactly to wire it, before or after the rcbo? the ground wire only after the galvanic isolator, correct? thanks a lot

Answer
W P. | Dec 19, 2023
User image of W P.

Unfortunately, the manufacturer does not provide an exact connection diagram. Ideally, you should install L- and N- wires of the LAR shore power indicator panel before the RCBO and the PE ground wire after the galvanic insulator. This allows an indication of a polarity reversal, even if the RCBO has tripped (for whatever reason) and the function of the galvanic isolator will also be taken into account.

E-mail Newsletter

Product news, offers & new guide videos. Stay up to date!

WhatsApp

New: Get news from SVB straight to your phone!

PHILIPPI Onboard System / Shore Panel Indicator Panel LAR
View Ratings (6) Questions (3)